PID Temperature Controller w/ Ramp/Soak (Relay Output)

$77.95


  • Model: SYL-2342P
  •  
     



    Qty.




Product Description:

PID Temperature Controller With 30 Steps Ramp/Soak

This is a brand new, dual display, 1/16 DIN (48 x 48 mm) programmable PID temperature/process controller. This controller is for applications where it is desirable to have automatically adjusting set points. Up to 30 steps can be programmed to A) ramp the temperature up or down at controlled rate, B) maintain the temperature for a specific period time, C) turn on/off the relays (alarm relay) after process reach a specific step. D) jump (for loops), run, hold and stop after process reaches a specific step. Common applications for this controller include controlling the temperature of glass kilns and heat treatment ovens.

This controller has all the features of the standard PID controller (except the manual control mode). The dual alarm relay can be activated by the temperature set point or program steps. They can be used for interlock other equipments in the process.

If you don't need the ramp/soak action, please see other PID controllers without ramp/soak option.

Features:

  • 30 programmable steps for ramp, soak and other logic actions
  • PID control with fuzzy logic enhancement
  • Dual alarm outputs as standard at no extra charge
  • 0.2% accuracy over the entire input range
  • Supports 17 different types of input devices that can be set by the user from keypad
  • Displays in either Fahrenheit or Celsius temperature unit
  • Percent output indication
  • Selectable security access levels
  • High brightness large LED display easily read from distance.
  • Manual, technical support and 90-days warranty

Main Specifications:

Input type TC: K, E, S, WRe, J, T, B, N
RTD: Pt100, Cu50, 0-80 ohm, 0-400 ohm.
DC voltage:0~20 mV, 0-100 mv, 0~5V, 1~5V, 0~1V, -100~100mV, -20~20mV, -5~5V, 0.2~1V.
DC current: 4~20mA.
Input range K (-60~2300ºF), S (-60~3100ºF), WRe (32~4150ºF), T (-330~660ºF),
E (32~1500ºF), J (32~1800ºF), B (32~3300ºF), N (32~2400ºF)
Pt100 (-320~1100ºF), Cu50 (-60~300ºF)
Linear input: -1999~+9999 defined by user
Display Two lines, Four digits. °F or °C.
Display Resolution 1°C and 0.1 °C. or 1°F
Accuracy ±0.2% or ±1 unit of full input range
Control mode Fuzzy PID, On-Off
Output mode Relay w/ NO and NC contacts: 7A at 240VAC, 10A at 120VAC, or 10A at 120VAC
Alarm Process high/low alarm, deviation high/low alarm
Alarm output Relay contact: 1A at 240VAC, 3A at120VAC, or 3A at 24VAC
Power supply
voltage rating
85~264VAC/50~60Hz
Front panel dimension 1.89 x 1.89", or 48 x 48 mm (1/16 DIN)

Default setting:

Input sensor: K type thermocouple (sensor not included)
Display Unit: Fahrenheit (°F)
Display resolution: 1 degree
Alarm 1: Deviation low
Alarm 2: Deviation high

Click here to download instruction manual (part 1).
Click here to download instruction manual (part 2).