A. Recommended part list: 
1) A programmable controller with ramp/soak function and dry relay output. 
Popular choice: SYL-2342P 
Ramp soak with USB/computer access: SYL-5342PA
Ramp soak with WiFi/App: AW-SYL-2342P
Ramp soak with LCD and Bluetooth: N20K48

2) If your actuator/solenoid valve consumes very limited amp (2A resistive or less), you may consider using the PID to drive it directly. Otherwise, you may consider using an exteranl contactor/relay, such as 
R30A (120V AC coil)
CN-PBC302-120V (120V AC coil)

3) A high temperature probe. We have one sealed high temperature probe can work a maximum of 2000F. It is good for glass kiln. It is listed at
WRNK-191

For some ceramic kiln, 2000F might not be high enough. Here is the sensor for it
TC-K-KLN

 

4) A project box, switch, and fuse that can be found from you local Radio Shark store.

Also, you can click HERE for the details about how to upgrade kiln with PID controllers.

 