PID Controller (Ramp Soak Related)

A1. Do I need a ramp soak PID, or a PID with timer?

It is based on your requirement. If you want to control the ramp up/down rate, or if you want to input a temperature & time profile (different temperature for different duration time), you need a PID controller with ramp soak.

If you want a simple timer function on this controller, like to start the timer once your oven reaches your set temperature, hold for one hour then stop the heater, you need a PID controller with a timer, like SWA-2451/SWA-2441 series.

A2. Introduction for Wireless (WIFI or Bluetooth) advanced PID controllers

We offer two advanced wireless PID controllers at this time. 

AW-SYL-2352: WIFI PID controller. It can be connected to your phone via your home router. iOS/Android app is provided. You can check/change all the parameters in the App. When the alarm is triggered, you will receive a push notification on your phone. It has a basic data plot in the app, time scale is 50mins or 2hours. You can also export the data through the app. 

N20K48: Bluetooth PID controller with short profile. You can use your phone/computer to get access to this PID via Bluetooth. iOS/Android/Win app is provided. You can check/change all the parameters in the App. No data plot nor push notifications in the mobile apps. Bluetooth connection via the mobile app is convenient and quick. No initial connection setup is required. It only takes a few seconds to connect to the controller every time. Ramp soak feature & timer feature is optional. Professional data logging feature & software is available via the external RS485 addon module. 

A3. Comparison table for ramp soak PIDs

Currently, Auber offers three different PID models with ramp soak:

SYL-23X2P Series, including SYL-2342P, SYL-2352P, SYL-2372P and also low voltage version SYL-2LX2P

SYL-53X2P Series USB controller, including SYL-5342PA and SYL-5352PA

N Series LCD controller N1050, N20K48

 

SYL-23X2P

SYL-53X2P

N1050

N20K48

Computer access

N

Y, RS485 & Windows software

Y, USB & Windows software

Y, USB & Bluetooth

Programming steps

30 ramp/soak steps

32 ramp steps and 32 soak steps (total of 64 steps)

4 steps per profile, up to 5 profiles (total of 20 steps)

9 steps per profile, up to 20 profiles (total of 180 steps)

Timer unit

Minute

Minute or Second

HH:MM or MM:SS HH:MM or MM:SS

Single step mode function

N

Y

Y

Y

Program ending alarm

N

Y

Y (By using separate timer)

Y (By using separate timer)

Separate timer

N

N

Y

Y

Temperature alarm

AL1 + AL2

AL1 only

Y

Y

Alarm suppression after power up

Y

N

Y (Initial blocking of alarm)

Y (Initial blocking of alarm)

Step jump by keypad

Y

Y

N

N

Force turn on/off relay by program values

Y

N

N

N

Power outage settings

Y

Y

Y

Y

Parameter lock modes

Y

Limited

Y

Y

Features

Best Selling Mode. Low voltage version available.

Computer access with Win software

Computer access with Win software. Built-in timer. Data Logging**

Similar to N1050 but it has Bluetooth, remoted control by phone app. Data Logging**.  Expandable capacity***

Limitation

No computer access.

It doesn’t have special command like SYL-23X2P. So you cannot program the step to jump/hold, or manually turn on alarm output. SSR output is 10V DC*.

SSR output is 5V DC*. Ramp soak steps is limited to 20.

SSR output is 5V DC*. RS485 function is only available for external add-on modules. 

*The SSR output for SYL-2352P is 12Vdc, which can drive 6 single phase SSRs in parallel OR 3 three-phase SSRs in parallel.

The SSR output for SYL-5352PA is 10Vdc, which can drive 5 single phase SSRs in parallel.

The SSR output for N1050/N20K48 is 5Vdc, which can drive 3 single phase SSRs in parallel OR 1 three-phase SSR. 

** Data logging feature requires the PID controller with RS485 port, such as N1050-B or N20K48 with the external RS485 module. Data logging feature cannot be achieved via Bluetooth, nor via the micro USB port on the side of the controller.

*** N20K48 has expandable design, so you can connect external modules to the base of the controller for different features, such as linear output module, RS485 module and WiFi module. See N20K48 listing for details. 

A4. Auber controller complexity level comparison

The table below shows the operational difficulty comparison for the different controller modules based on Auber's opinion.

Controller model Difficulty level
SYL-2342/SYL-2352/SYL-2372/DSPR1/DSPR-5 0 (Easiest)
SYL-1512A/SYL-2362/SYL-2381/
SWA-2441B/SWA-2451B/DSPR120/DSPR220
1
SYL-2342P/SYL-2352P/SYL-2372P/DSPR310D/DSPR320A 2
SYL-5352PA/SYL-5342PA/N1050/N20K48 3 (Hardest)

Controllers by type:

Universal controller (with both SSR and relay outputs): SYL-1512A, SYL-2362, N1050, N20K48
Specific controller (with only one main output, either SSR OR relay output): SYL-2342/SYL-2352/SYL-2372, SWA-2441B/SWA-2451B, SWA-2442C/SWA-2452C, SYL-2342P/SYL-2352P/SYL-2372P, SYL-5352PA/SYL-5342PA
Controllers with computer access & Win software: SYL-5352PA/SYL-5342PA, N1050, N20K48
Controllers with iOS/Android apps: AW-SYL-2352, N20K48
Wireless PID controllers: AW-SYL-2352/2342/2352P/2342P (WIFI), N20K48 (Bluetooth)
Controllers with linear output: SYL-2381 (mA variation)
Controllers which can read linear inputs: SYL-2342/SYL-2352/SYL-2372, SYL-2342P/SYL-2352P/SYL-2372P, N20K48
Controllers with a built-in timer: SWA-2451B/SWA-2441B, N1050, N20K48

A5. Comparison table for wireless ramp soak PIDs

Currently, Auber offers three ramp soak PID with remote access:

  AW-SYL-23X2P N20K48 N20K48 with WiFi module
Wireless Feature 2.4G WiFi Bluetooth Bluetooth + 2.4G WiFi
Wireless Control Type App based App based App based (Bluetooth & Intranet);
Web based (Internet, Novus Cloud)
Notification Type Push N.A.

Email only (free plan);
SMS (paid plan)

Program Steps 30 steps 9 steps per profile, up to 20 profiles (total of 180 steps)
Timer Unit Minute HH:MM or MM:SS
Computer access N.A. Win software (via Micro USB port or Bluetooth)
Output Type 12V DC SSR output (2352P), or 10A dry relay output (2342P) 5V DC SSR output and 3A dry relay output. Addon relay modules can be installed for more outputs. 
Note 1 Alarm relays can be forced turned on in the steps Ramp soak feature can be enabled/disabled on user end.
Note 2 User can start/stop/pause the program in the app and by the front keypad. User can start/stop the program by chnaging the status parameter in the app and by the front keypad. No pause function.
Note 3 No Bluetooth. WiFi connection requires a router. Mobile apps are only for the Bluetooth, not compatible with WiFi connection. Mobile apps can only allow you to change settings. No temp reading nor data plot in the mobile apps. (Novus Cloud) Unable to change settings in the web portal.

 

 