Digital Differential Outlet Thermostat for Attic Ventilation

(image for) Digital Differential Outlet Thermostat for Attic Ventilation
Digital Differential Outlet Thermostat for Attic Ventilation
  • Model: TD340

(image for) Ask a Question

$99.99

Add to Cart:
Product Update (8/27/2024): The new model TD340 with a two-stage heating & cooling control is now available! Please read the TD340 user manual for details. It replaces the older model TD330. 
 
TD340 model updates: 
  • New control logic. Now support two-stage heating and/or cooling control. 
  • Flexible output sockets configuration.   
 
The TD340 is a temperature controller for heating, ventilating, and air-conditioning (HVAC) controls using an external medium such as air or water. The controller comes with two sensors. The primary sensor (Sensor1) should be placed in the room or close to the object where the temperature needs to be regulated. The auxiliary sensor (Sensor2) should be placed to monitor the temperature of the external medium. The temperature difference between the two sensors can be used as an additional criterion for controlling the power output.
 
Two independent channels are available, and each channel has its own set temperature. There are two output sockets, one for cooling and one for heating. The controller also offers the flexibility of re-assigning the heating or cooling output to one or both sockets per the user’s setting.
 
This controller is a plug-and-play controller that requires no wiring. Both the heating and cooling control modes have simple on/off control, similar to a mechanical thermostat but with higher precision due to an adjustable hysteresis band, precise sensors, and digital readouts.  An anti-short function is provided for cooling output to protect the compressor from frequently cycling on/off during high-pressure Freon. 
 
Two digital silicon band gap sensors are used. The advantage of this sensor is that it is more reliable in moist environments than thermistor sensors. This digital sensor can also be immersed over extended periods of time. They also have a more uniform accuracy over an entire specified temperature range. Two sensors are interchangeable. One of the sensors has a 12-feet (2 m) cable, which makes it easy to reach the external medium. For customized sensor cable length, please contact us.
 
Specifications
Temperature Control Range
 -50°C ~ 105°C, -58°F ~ 221°F
Temperature Resolution
0.1°C (between -9.9°C ~ 99°C)
1°C (between -50°C ~ 10°C and 100°F ~ 120°C)
0.1°F (between -9.9°F ~ 99.9°F )
1°F (between -58°F ~ 10°F and 100°F ~ 248°F)
Temperature Accuracy
0.5°C or 0.9°F
Temperature Control Mode
On/Off Control; Heating and Cooling.
Temperature Control Output
10 A, 120 V or 240 V AC *
Audio Alarm
High and Low Limit
Sensor Type
Silicon Band Gap Sensor
Sensor Size
0.24" O.D. (6.0 mm), 2" long (50 mm)
Operating Temperature
-20°C ~ 50°C (0°F ~ 120°F)
Dimension
3.6'’ x 5.5'’ x 1.8'’ (91 x 140 x 46 mm)
Input Power 
85 ~230 VAC, 50Hz/60Hz
Sensor1 Cable Length
6 ft (2 m)
Sensor2 Cable Length 12 ft (4 m)
Power Cable Length
3ft (1m)
Warranty
One (1) year limited warranty

Notes:

  • The controller can display temperature in Celsius or Fahrenheit.
  • Unlike the PID controllers we sell, this on/off controller will not hold the temperature as tightly if the system has a very slow and delayed response. Some temperature overshoot is normal.
  • Either the heating or the cooling device is limited to 10 Amps. The output voltage is the same as the input voltage.  When the controller is plugged into 120 VAC, the output will be 120 VAC. If the controller is connected to 240 VAC, the output will be 240 VAC as well.
  • The input power plug is a US NEMA 5-15P plug. The output sockets are US NEMA 5-15R. Optional input & output travel plug adapters are offered. Please check here for more details.
  • Refurbished TD330/TD340 might be in limited stock here. 
  • TD330 model updates (compared to TD320): 
    • Output sockets have been modified to standard US NEMA 5-15 receptacles.
    • Sensor connectors have been changed to standard-size 3-pin connectors for easier handling.
    • A new parameter, Relay Output Mode, has been added to allow users to reassign the heating or cooling output to one or both sockets per the user’s specific application.  